204
SECTIO
N
8
Dat
a
Coding Tab
le
s
RFID System
User's Manual
SECTION 8
Appendices
Data Coding Tables
Special I/O Unit Words Allocated in DM Area
First word allocated to Antenna 1: m = (100
×
Unit number)
First word allocated to Antenna 2: m = (100
×
(Unit 1))
System Settings: DM m (= D2
@@
00)
Auto Wait Time Setting: DM m+1 (= D2
@@
01)
UID
Addition Setting
Test Mode
Disable Setting
Test Mode Disable
Setting (BCD)
15 14 13 12 11 10
9
8
Tag Communications
Speed Setting
7
6
5
4
3
2
1
0
0: Normal Mode
1: High-speed Mode
UID Addition
Setting (BCD)
0: Disabled
1: Enabled
DM address
Meaning
D2
@@
00
Setting for Write
Verification
0: Enabled
1: Disabled
Setting for Write
Verification (BCD)
0: Verification
1: No verification
Tag Communications
Speed Setting (BCD)
DM address
Meaning
D2
@@
01
A
u
to
W
ait Time Setting
A
u
to
W
ait Time Setting
15 14 13 12 11 10 9
8
7 6 5 4 3 2 1 0
0000: Infinity (not monitored)
0001 to 9999 (hex)
×
0.1 s
Содержание CJ1W-V680C11
Страница 62: ...60 SECTION 3 Connections and Wiring RFID System User s Manual SECTION 3 CJ series ID Sensor Units MEMO...
Страница 78: ...76 SECTION 4 I O Data Allocations RFID System User s Manual SECTION 4 Data Exchange with the CPU Unit MEMO...
Страница 118: ...116 SECTION 5 RF Tag Memory Error Correction RFID System User s Manual SECTION 5 ID Sensor Unit Functions MEMO...
Страница 158: ...156 SECTION 7 Troubleshooting RFID System User s Manual SECTION 7 Troubleshooting Alarms and Errors MEMO...