SECTION 5
Write P
rotection
SECTION 5
ID Sensor Unit Functions
103
RFID System
User's Manual
Start Address Greater Than End Address
All addresses from the start address to the final address and all addresses from address 0004 hex to
the end address in the RF Tag, inclusive, will be write-protected.
The write protection setting area in the RF Tag is not write-protected.
Clearing Write Protection Using the V680 Method
To temporarily clear write protection, e.g., to overwrite the write-protected data, turn OFF the MSB of
address 0000 hex in the RF Tag.
Application Precaution for Write Protection
Write protection is implemented by the ID Sensor Unit. It will not be effective for Reader Writers from other companies.
Address (hex)
Upper digit
Lower digit
0000
1
0
0
0
0
0
0
1
8
1
0001
0
0
1
0
0
0
0
0
2
0
0002
0
0
0
0
0
0
0
0
0
0
0003
0
0
0
1
0
1
0
1
1
5
0000 hex
0120 hex
Write-protected
0004 hex
0015 hex
Write-protected
End address
Start address
03E7 hex
Содержание CJ1W-V680C11
Страница 62: ...60 SECTION 3 Connections and Wiring RFID System User s Manual SECTION 3 CJ series ID Sensor Units MEMO...
Страница 78: ...76 SECTION 4 I O Data Allocations RFID System User s Manual SECTION 4 Data Exchange with the CPU Unit MEMO...
Страница 118: ...116 SECTION 5 RF Tag Memory Error Correction RFID System User s Manual SECTION 5 ID Sensor Unit Functions MEMO...
Страница 158: ...156 SECTION 7 Troubleshooting RFID System User s Manual SECTION 7 Troubleshooting Alarms and Errors MEMO...
Страница 213: ......