138
SECTIO
N
6
Communica
tions
Comman
d
s
RFID System
User's Manual
SECTION 6
Controlling the ID Sensor Unit
Write with Error Correction
Writes the designated data to the RF Tag beginning from the specified start address, and writes the RF
Tag memory check code and error correction code to the next 5 bytes of memory. Do not change this
code. It is required by the Read with Error Correction command.
Up to 510 bytes (i.e., 255 words) can be specified for one command execution.
• Verification will not be performed if No Verification is set for writing.
• Check the memory capacity of the RF Tag before setting the Processing Address and Number of Processing Bytes. If
the Processing Address and Number of Processing Bytes are not suitable for the RF Tag for which communications
are being performed, the RF Tag Address Error Flag (CIO n+8, bit 13) will turn ON.
• The five bytes of data after the area extending from the Processing Bytes is the check code area. Do not write any
data to the check code area.
• Check the memory capacity of the RF Tag before setting the Processing Address and Number of Processing Bytes. If
the Processing Address and Number of Processing Bytes are not suitable for the RF Tag for which communications
are being performed, the RF Tag Address Error Flag (CIO n+8, bit 13) will turn ON.
Word address
Bit No.
Type
Bit name
Description
Antenna 1 of
CS1W-V680C11,
CS1W-V680C12,
CJ1W-V680C11,
or CJ1W-V680C12
Antenna 2 of
CS1W-V680C12
or
CJ1W-V680C12
n+1
n+11
08 to 15
Command
Command code
0B hex
04 to 07
Communications
Specification
Specify the communications method with
the RF Tag.
0
Trigger
1
Single auto
2
Repeat auto
3
FIFO trigger
4
FIFO repeat
5
Multi-access trigger
6
Multi-access repeat
00 to 03
Processing
Specification
Specify the write data storage order.
0
Leftmost
→
Rightmost
1
Rightmost
→
Leftmost
n+2
n+12
00 to 15
Processing
Address
Specify the first RF Tag address to write.
Setting range: 0000 to FFFA hex
n+3
n+13
00 to 15
Number of
Processing Bytes
Specify the number of RF Tag write bytes.
Setting range: 0001
to 01FE hex
n+4
n+14
00 to 15
Data
storage
area
Data Storage
Word Address
(rightmost 4 digits)
Specify the write data storage destination
n+5
n+15
12 to 15
Data Storage Area
08 to 11
Bank Specification
00 to 07
Data Storage
Word Address
(leftmost 2 digits)
n+6
n+16
00 to 15
Option
Command Option
0000 hex
Содержание CJ1W-V680C11
Страница 62: ...60 SECTION 3 Connections and Wiring RFID System User s Manual SECTION 3 CJ series ID Sensor Units MEMO...
Страница 78: ...76 SECTION 4 I O Data Allocations RFID System User s Manual SECTION 4 Data Exchange with the CPU Unit MEMO...
Страница 118: ...116 SECTION 5 RF Tag Memory Error Correction RFID System User s Manual SECTION 5 ID Sensor Unit Functions MEMO...
Страница 158: ...156 SECTION 7 Troubleshooting RFID System User s Manual SECTION 7 Troubleshooting Alarms and Errors MEMO...
Страница 213: ......