42
SE
C
T
IO
N
2
Co
nnec
tions
and Wir
in
g
RFID System
User's Manual
SECTION 2
CS-series ID Sensor Units
Wiring the External Power Supply (CS1W-V680C12 Only)
Wire the power supply as shown below.
M3 self-lifting screws are used as the connection terminals for the power supply. When necessary, use
the following crimp terminals. The tightening torque is approximately 0.58 N·m.
Examples of Applicable Crimp Connectors
Recommended DC Power Supplies (Compact, DIN Track-mountable,
manufactured by OMRON)
•
Although adequate measures have been taken inside the ID Sensor Unit for noise entering on the power supply line, supplying
power through a line filter can be used to greatly attenuate ground noise.
•
Although the rated power consumption of the CS1W-V680C12 is 360 mA at 24 VDC, be sure to consider the surge current
when determining capacities.
•
When using the CS1W-V680C12, turn ON the power supply for external inputs at the same time or after the CPU Unit power
supply is turned ON.
Manufacturer
Model number
Applicable wire size
Shape
J.S.T Mfg. Co., Ltd.
1.25-N3A
AWG26 to 18
Forked
J.S.T Mfg. Co., Ltd.
1.25-Y3A
Model number
Output capacity
Input voltage
S8VS-03024
24 VDC, 1.3 A
100 to 240 VAC
CS1W-V680C12
Line filter
+24 V DC
0 V
Connection Example
6.5 mm max.
(For M3 terminal)
Содержание CJ1W-V680C11
Страница 62: ...60 SECTION 3 Connections and Wiring RFID System User s Manual SECTION 3 CJ series ID Sensor Units MEMO...
Страница 78: ...76 SECTION 4 I O Data Allocations RFID System User s Manual SECTION 4 Data Exchange with the CPU Unit MEMO...
Страница 118: ...116 SECTION 5 RF Tag Memory Error Correction RFID System User s Manual SECTION 5 ID Sensor Unit Functions MEMO...
Страница 158: ...156 SECTION 7 Troubleshooting RFID System User s Manual SECTION 7 Troubleshooting Alarms and Errors MEMO...
Страница 213: ......