14
Operating Procedure
Section 3-1
3-1
Operating Procedure
Follow the procedure outlined below for preparing the C200H
prior to oper-
ating the Cam Positioner Unit.
1,2,3...
1.
Set the switches (Refer to 2-2 Switch Settings). Set the front and rear panel
switches according to the operating conditions.
2.
Mount the Unit to the Rack. Be careful to turn off the power supply to the
C200H
before mounting the Cam Positioner Unit to the Rack or removing
it from the Rack.
3.
Wire the external cam outputs (Refer to 2-3 Wiring). Until the trial operation
has been completed, do not directly connect a load. Instead, connect to an
object (such as the G7TC-OC16) for which the external cam output status
is known.
4.
Connect the resolver and the Data Setting Console (Refer to 2-3-2 Resolv-
er Connection Cable and 2-3-3 Data Setting Console Cables). Use the
specified connection cable for connecting the resolver and the Data Setting
Console.
5.
Turn ON the C200H
and external cam output power supply. Place the
C200H
in program mode.
6.
Set the data with the Data Setting Console. Set the RUN/PRG selector
switch to PRG before setting the data.
7.
Set the bank that is to be executed. Set the RUN/PRG selector switch to
RUN. Set the number of the bank to be executed in word n + 1.
(n = 100 + 10 x Unit no.)
8.
Turn ON the Operation Flag. Turn ON bit 00 of word n (the Operation Flag).
Содержание C200H-CP114
Страница 1: ...23 5 7 21 0 18 Cat No W224 E1 2 SYSMAC C200H CP114 Cam Positioner Unit...
Страница 2: ......
Страница 3: ...C200H CP114 Cam Positioner Unit Operation Manual Revised January 2001...
Страница 4: ...iv...
Страница 6: ...vi...
Страница 8: ......
Страница 10: ......
Страница 59: ...45 SECTION 5 Troubleshooting This section provides possible errors and corrections Error Detection 46...
Страница 70: ......