48
Error Detection
Section 5
Display and Output to the Input Relay
(n = 100 + 10 x Unit No.)
Error Clearing Methods
When any of the above errors occurs, first remove the cause of the error and
then apply one of the following methods to clear the error. Only methods (3)
and (4) are valid for parameter errors (
). When either of these two methods
is used to clear an error, the bank number reverts to “0” and must then be
reset.
• Press the CLR key on the Data Setting Console.
• Turn the Error Reset Flag (bit 03 of word n) from OFF to ON.
• Turn the C200H
’s power supply from ON to OFF and then back ON.
• Turn the Special I/O Restart Flag (AR 0100 to AR 0109) from OFF to ON.
Duplicate I/O Unit
The Unit number duplicates the number of another Special I/O Unit. The SR
bit 25415 turns ON when an Duplicate I/O Unit error occurs. Refer to AR 0000
to AR 0011 for the duplicated Unit number. The C200H
PC will not operate
during a duplicate I/O error.
Set the Unit number to a unique number.
Special I/O Unit Error
I/O refresh not operating correctly between the CPU Unit and Cam Positioner
Unit. Operation in not interrupted when a Special I/O Unit error occurs. Refer
to AR 0000 to AR 0015 for the Unit number where the error occurred. After
correcting the cause of the error, set the Special I/O Unit Restart Flag (AR
0100 to AR 0109) to restart operation.
RUN Indicator Unlit
The C200H
power supply is turned on but the RUN indicator is not lit. None
of the errors described previously is the cause. Replace the Unit.
No Data Detting console
Display
• No 24 VDC power supply is connected to the Cam Positioner Unit input
terminals A10 and B10.
• The connecting cable connector is disconnected.
• The connecting cable is broken.
• A circuit in the Data Setting Console is defective.
• A circuit in the Cam Positioner Unit is defective.
After determining the cause of the error, repair the problem or replace the
Unit.
Error
Cam Positioner Unit
display
Data Setting Console display
Output to input relay
Word (n+8)
Bit 07 to
00 of
word
(n+9)
RUN
ALM
DATA
RUN
ALM1
ALM2
Bit 14
Bit 15
Memory error
Lit
Lit
(Blinking)
Not lit
Not lit
Lit
OFF
ON
01
Communication
error
Lit
Lit
Lit
Not lit
Lit
OFF
ON
02
Power failure
error
Lit
Lit
Not lit
Not lit
Lit
OFF
ON
03
Bank change
error
Lit
Lit
Not lit
Not lit
Lit
OFF
ON
20
Data transfer
error
Lit
Lit
Lit
Not lit
Lit
OFF
ON
21
Parameter error
Lit
Lit
Lit
Not lit
Lit
OFF
ON
22
Resolver dis-
connection error
Lit
Lit
Not lit
Lit
Not lit
ON
OFF
10
Содержание C200H-CP114
Страница 1: ...23 5 7 21 0 18 Cat No W224 E1 2 SYSMAC C200H CP114 Cam Positioner Unit...
Страница 2: ......
Страница 3: ...C200H CP114 Cam Positioner Unit Operation Manual Revised January 2001...
Страница 4: ...iv...
Страница 6: ...vi...
Страница 8: ......
Страница 10: ......
Страница 59: ...45 SECTION 5 Troubleshooting This section provides possible errors and corrections Error Detection 46...
Страница 70: ......