16
Nomenclature and Functions
Section 3-2
2.
If a resolver is not connected, “
” will blink. Should this occur, follow the
procedure outlined below to turn it off. In any case, data can still be set
even if no resolver is connected. To do that, carry out only d) and e) below.
a) Turn OFF the power supply to the C200H
.
b) Connect a resolver.
c)
Turn ON the power supply to the C200H
.
d) Set the operation mode selector to PRG.
e) Press the CLR Key.
3-2-2
Functions
Display Functions
Data Display
Operation Displays
Name
Function
DATA
Depending on the “MODE” setting number, the following data will be displayed.
Data concerning cam output ON/OFF settings, protect settings, and settings for the number of revo-
lutions required for a single process.
The process execution conditions and present cam angle will be displayed.
MODE
Modes 1 to 6 will be displayed. The mode that can be selected will vary according to the setting of the
RUN/PRG switch.
When PRG is set:
Mode 3: Cam data setting mode
Mode 4: Protect setting mode (*)
Mode 5: Mode for setting the number of revolutions required for a single process
(*)
Cannot be selected when pin 2 of the rear panel DIP switch is ON (i.e., when protection is not
permitted).
When RUN is set:
Mode 1: Mode for setting the number of cycles for the processes to be executed
Mode 2: Present cam angle monitor mode
Mode 6: Adjustment operation mode (*)
(*)
Cannot be selected when pin 3 of the rear panel DIP switch is ON (i.e., when adjustment opera-
tion is not permitted).
BK
Banks 1 to 8 will be displayed.
In Modes 1, 2, and 6, the number of the bank to be executed will be displayed.
In Mode 5, nothing will be displayed.
CAM
Cam output numbers from 1 to 48 will be displayed. These will only be displayed in Modes 3, 4, and 6,
however, and not in Modes 1, 2, and 5. Numbers 1 to 16 are for internal/external cam outputs, and
numbers 17 to 48 are for internal cam outputs.
STEP
Step numbers 1 to 7 will be displayed. These will only be displayed in Modes 3 and 6, however, and not
in Modes 1, 2, 4, and 5. Seven ON/OFF settings can be made for each cam output.
Name
Function
ON
When this indicator is blinking, the cam angle can be set for when cam output is ON.
OFF
When this indicator is blinking, the cam angle can be set for when cam output is OFF.
RUN
Lit while the Cam Positioner Unit is in operation. While this indicator is lit, cam outputs will turn ON and
OFF. The procedure for operating the Cam Positioner Unit is as outlined below.
(1) Set the Cam Positioner Unit’s RUN/PRG selector to RUN.
(2) Set banks 1 to 8 at word n + 1.
(3) Turn ON bit 00 of word n (Operation Flag).
(n = 100 + 10 x Unit no.)
ALM1
Lit if the resolver is accidentally disconnected.
ALM2
Lit if any of the following errors occur.
Memory error
Bank selection error
Power failure error
Communications error
Memory load error
Parameter error
Содержание C200H-CP114
Страница 1: ...23 5 7 21 0 18 Cat No W224 E1 2 SYSMAC C200H CP114 Cam Positioner Unit...
Страница 2: ......
Страница 3: ...C200H CP114 Cam Positioner Unit Operation Manual Revised January 2001...
Страница 4: ...iv...
Страница 6: ...vi...
Страница 8: ......
Страница 10: ......
Страница 59: ...45 SECTION 5 Troubleshooting This section provides possible errors and corrections Error Detection 46...
Страница 70: ......