
23
Data Setting and Monitoring
Section 3-3
When changing the number of the bank to be executed, first make the
change in word n + 1, and then turn the Operation Flag from ON to OFF,
and then ON again.
Monitoring of the Present Cam Angle (Mode 2)
1,2,3...
1.
Set the RUN/PRG selector switch to RUN.
If RUN is already selected, then proceed directly to (2).
2.
Press the Return Key, the Up Key, or the Down Key to cause the Mode 2
indicator to blink.
Press the Return Key, the Up Key, or the Down Key.
The MODE indicator will blink.
Press either the Up Key or the Down Key until “2” is displayed.
3.
Press the Return Key to enter mode “2.”
During operation, cam outputs will turn ON and OFF in response to the
present cam angle, according to the ON and OFF angle setting data of the
bank that is executed.
If the bank number is set to “0,” then there will be no cam output.
Adjustment Operation (Mode 6)
1,2,3...
1.
Set the RUN/PRG selector switch to RUN.
If RUN is already selected, then proceed directly to (2).
Present cam angle
Mode no.
Execution bank no.
0: No cam output
1 to 8: Bank no.
ON/OFF angle
Mode no.
ON angle
OFF
angle
Execution bank no.
Step no.
Cam output no.
Содержание C200H-CP114
Страница 1: ...23 5 7 21 0 18 Cat No W224 E1 2 SYSMAC C200H CP114 Cam Positioner Unit...
Страница 2: ......
Страница 3: ...C200H CP114 Cam Positioner Unit Operation Manual Revised January 2001...
Страница 4: ...iv...
Страница 6: ...vi...
Страница 8: ......
Страница 10: ......
Страница 59: ...45 SECTION 5 Troubleshooting This section provides possible errors and corrections Error Detection 46...
Страница 70: ......