41
Program Examples
Section 4-3
Cam Data
The cam ON/OFF data is set in blocks of 8 words starting at DM 3000 as
shown below.
The following table shows example data for one block, i.e., cam ON/OFF data
for 15 words.
Note Set 0000 or 0FFF for steps that are not being used.
Program Execution
Procedure
The program functions as follow to transfer the data:
1,2,3...
1.
Block 1 of data starting at DM 5000 is transferred to the normal DM Area
words starting at DM 0000.
2.
The Memory Download Bit (bit 05 of word n) is turned ON to download the
data from the normal DM Area words to the Cam Positioner Unit.
3.
When the transfer has been completed, block 2 of data is transferred to the
normal DM Area words and the process is repeated.
4.
The same processing is performed for blocks 3 to 6.
Address
Block
Cam output
numbers
DM 3000 to DM 3119
1
1 to 8
DM 3200 to DM 3319
2
9 to 16
DM 3400 to DM 3519
3
17 to 24
DM 3500 to DM 3719
4
25 to 32
DM 3600 to DM 3919
5
33 to 40
DM 4000 to DM 4119
6
41 to 48
1
2
3
4
5
6
Address
Contents
Meaning
DM 3000
0101
Upper 2 digits: Bank number (1 to 8)
Lower 2 digits: Cam output number (1 to 8)
DM 3001
0030
Step 1 ON data
DM 3002
0050
Step 1 OFF data
DM 3003
0080
Step 2 ON data
DM 3004
0115
Step 2 OFF data
DM 3005
0150
Step 3 ON data
DM 3006
0200
Step 3 OFF data
DM 3007
0260
Step 4 ON data
DM 3008
0320
Step 4 OFF data
DM 3009
0000
Step 5 ON data
DM 3010
0000
Step 5 OFF data
DM 3011
0000
Step 6 ON data
DM 3012
0000
Step 6 OFF data
DM 3013
0000
Step 7 ON data
DM 3014
0000
Step 7 OFF data
Содержание C200H-CP114
Страница 1: ...23 5 7 21 0 18 Cat No W224 E1 2 SYSMAC C200H CP114 Cam Positioner Unit...
Страница 2: ......
Страница 3: ...C200H CP114 Cam Positioner Unit Operation Manual Revised January 2001...
Страница 4: ...iv...
Страница 6: ...vi...
Страница 8: ......
Страница 10: ......
Страница 59: ...45 SECTION 5 Troubleshooting This section provides possible errors and corrections Error Detection 46...
Страница 70: ......