17
Data Setting and Monitoring
Section 3-3
Operation Key Functions
3-3
Data Setting and Monitoring
Setting Items
For Modes 3, 4, and 5, set the RUN/PRG selector to PRG.
Mode 4 is valid only when pin 2 of the rear panel DIP switch is OFF (i.e., when
protection is permitted).
Mode 6 is available only when pin 3 of the rear panel DIP switch is OFF (i.e.,
when adjustment operation is permitted). For Mode 6, set the RUN/PRG
selector to RUN.
Name
Function
Return Key
When beginning a setting change, press the Return Key, the Up Key, or the Down Key. The MODE
number will then blink. Each time the Return Key is pressed, the set value that is blinking will be
entered and the next item to be set will start blinking.
Up Key
When beginning a setting change, press the Return Key, the Up Key, or the Down Key. The MODE
number will then blink. Press the Up Key to increment the number that is blinking. When making a
DATA setting, press the Up Key continually to successively increment the number.
Down Key
When beginning a setting change, press the Return Key, the Up Key, or the Down Key. The MODE
number will then blink. Press the Up Key to decrement the number that is blinking. When making a
DATA setting, press the Up Key continually to successively decrement the number.
Reverse Key
When the Reverse Key is pressed, the setting item that is currently blinking will stop and the previous
item will start blinking. To finish making settings in a given mode, use the Reverse Key to return to the
blinking MODE display and then press the Reverse Key again. The blinking display will then stay lit and
the settings will be complete.
Clear Key
When the Clear Key is pressed, all data below the blinking item will be cleared. For example, if “1” is
blinking for BK, all of the data for bank no. 1 will be cleared. When the Clear Key is pressed once, the
item that is to be cleared will start blinking. If the Clear Key is then pressed a second time, the data will
be cleared. To cancel the clear, press any Key other the Clear Key before pressing the Clear Key the
second time. This function does not exist in the adjustment operation mode (mode 6). Press the Clear
Key to clear an error display.
MODE
Setting
item
Name
Setting range
3 (Cam data
setting)
6 (Adjustment
operation)
BK
Bank no.
1 to 8
In Mode 6, the setting (i.e., the number of the bank to be
executed) is made from the C200H
user’s program or a
peripheral device.
CAM
Cam output no.
1 to 48
1 to 16:
internal/external cam output
17 to 48:
Internal cam output
STEP
Step no.
1 to 7
ON
ON angle
0 to 359
OFF
OFF angle
4 (Protect set-
ting)
BK
Bank no.
1 to 8
CAM
Cam output no.
1 to 48
1 to 16:
internal/external cam output
17 to 48:
Internal cam output
DATA
Not protected
“
”
Protected
“
”
5 (Number of
revolutions
required for a
single
process)
DATA
Decimal point position
2 digits to right of decimal
1 digit to right of decimal
0 digits to right of decimal
Set the number of resolver
revolutions required for a sin-
gle process cycle.
Data
0.01 to 9.99
0.1 to 99.9
1 to 999
Содержание C200H-CP114
Страница 1: ...23 5 7 21 0 18 Cat No W224 E1 2 SYSMAC C200H CP114 Cam Positioner Unit...
Страница 2: ......
Страница 3: ...C200H CP114 Cam Positioner Unit Operation Manual Revised January 2001...
Страница 4: ...iv...
Страница 6: ...vi...
Страница 8: ......
Страница 10: ......
Страница 59: ...45 SECTION 5 Troubleshooting This section provides possible errors and corrections Error Detection 46...
Страница 70: ......