11
Wiring
Section 2-3
2-3-2
Resolver Connection Cable
To connect a resolver to the C200H-CP114 Cam Positioner Unit, use the
3F88L-CR0R2A Auxiliary Connection Cable which is provided with the Unit.
To extend the cable for a 3F88L-RS17 or 3F88L-RS17T Resolver, use 3F88L-
CR
C Extension Cable. The total length of the connection cables must
not exceed 100 meters, or an operation error may result.
Note Secure the resolver cable so that no external force will be imposed on the
auxiliary connection cables.
Inserting Connectors into the Unit
Connector Pin Wiring
20 cm
CP114
ALM
ADJ
RUN
Connector for resolver
Insert the connector so that the cable
will be pointing downward.
1
2
3
4
5
6
7
8
Sin(+)
Sin(
−
)
Cos(+)
Cos(
−
)
OUT(+)
OUT(
−
)
1
2
3
4
5
6
7
8
Sin(+)
Sin(
−
)
FG
Cos(+)
Cos(
−
)
FG
10
11
...
15
OUT(+)
OUT(
−
)
FG
9
Cam Positioner
Unit
Resolver
Connector
case
Connector
case
---
---
---
---
---
---