XtraDrive User Manual
Chapter
5
: Parameter Settings and Functions
5-57
Parameter Setting
Set the following parameter so that the input signal /P-CON
(/ZCLAMP) can be used to enable or disable the zero clamp function.
Parameter Signal Setting
(ms)
Description
Pn000.1
Control Method
Selection
Default Setting: 0
Speed Control
Input /P-CON CN1-41
Proportional Control, etc.
Speed/Torque Control,
Position Control
Note:
The /ZCLAMP signal can be used when an input circuit signal is allocated. See
5.3.3 Input Circuit
Signal Allocation
for more details.
Pn000.1 Setting
Control Mode
CN1-5
CN1-41
V-REF
/P-CON
(/ZCLAMP)
Zero clamp
Speed reference
XtraDrive
A
Zero Clamp Control Mode
This mode allows the zero clamp function
to be set when the servomotor stops.
•
The speed reference is input from V-
REF (CN1–5).
•
/P-CON (/ZCLAMP)(CN1–41) is used
to turn the zero clamp function ON and
OFF.
CN1-41 is open (OFF).
Turns the zero clamp function OFF.
CN1-41 is 0V (ON).
Turns the zero clamp function ON.
Zero clamp is performed when the following
two conditions are satisfied:
•
/P-CON (/ZCLAMP) is ON.
•
Speed reference is below the setting
designated at Pn501.
Setting Motor Speed
Use the following parameter to set the motor speed level at which zero
clamp is performed
Parameter Signal Setting
(rpm)
Description
Pn501
Zero Clamp Level
Setting Range: 0 to 10000
Default Setting: 10
Speed Control
If zero clamp speed control is selected, set the motor speed at which
zero clamp is to be performed. The maximum speed will be used if the
value of Pn501 is set higher than the maximum speed of the
servomotor.
Zero Clamp Conditions
Zero clamp is performed when all the following conditions are satisfied:
•
Zero clamp speed control is selected (parameter Pn000.1 is set to A).
•
/P-CON (/ZCLAMP)(CN1-41) is ON (0V).
•
Speed reference drops below the setting level of Pn501.
Содержание 8U0108-E1-01
Страница 4: ...iv This page intentionally left blank...
Страница 6: ...vi This page intentionally left blank...
Страница 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Страница 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Страница 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Страница 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Страница 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Страница 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Страница 48: ...XtraDrive User Manual Chapter 3 Wiring 3 24 Absolute Serial Encoders Incremental A B C Encoders...
Страница 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Страница 240: ...XtraDrive User Manual Chapter 8 Ratings Specifications and Dimensional Drawings 8 11 8 5 2 XD 04 1 phase 200 V 400 W...
Страница 332: ......