XtraDrive User Manual
Chapter
5
: Parameter Settings and Functions
5-40
The maximum speed of the servomotor will be used if Pn407 is set to a
value higher than the maximum speed of the servomotor.
External Speed Limit Function:
This function sets the voltage range for speed reference input V-REF
(CN1-5) according to the output range of the host controller or external
circuit.
When the default setting (600) is multiplied by 0.01V, the result (6V)
corresponds to the rated motor speed.
Parameter
Signal
Setting
Control Mode
Pn300
Speed Reference
Input Gain
Setting Range: 150 to 3000
Default Setting: 600
Speed/Torque
Control
The default setting is 6V = the rated motor speed.
Principle of Speed Limit
When the control speed range is exceeded, the torque, which is
inversely proportional to the difference between the speed limit and the
actual speed, is fed back in order to return the system to a level within
the control speed range. In effect, the actual motor speed limit depends
on the load condition.
Motor
speed
V-REF
Speed limit
range
5.2.8. Torque
Feed-Forward Function
The torque feed-forward function is used only in speed control (analog
reference). This function is used to:
•
Shorten positioning time
•
Differentiate a speed reference at the host controller to generate a
torque feed-forward reference
•
Input this reference together with the speed reference to the servo
amplifier
Too high a torque feed-forward value will result in an overshoot or an
undershoot. To prevent this, set the optimal value while closely
observing the system response.
Connect a speed reference signal to V-REF (CN1-5 and 6) and a torque
feed-forward reference signal to T-REF (CN1-9 and 10).
Содержание 8U0108-E1-01
Страница 4: ...iv This page intentionally left blank...
Страница 6: ...vi This page intentionally left blank...
Страница 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Страница 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Страница 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Страница 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Страница 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Страница 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Страница 48: ...XtraDrive User Manual Chapter 3 Wiring 3 24 Absolute Serial Encoders Incremental A B C Encoders...
Страница 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Страница 240: ...XtraDrive User Manual Chapter 8 Ratings Specifications and Dimensional Drawings 8 11 8 5 2 XD 04 1 phase 200 V 400 W...
Страница 332: ......