XtraDrive User Manual
Appendix D
:
List of Parameters
D-6
*
After changing this parameter, cycle the main circuit and control power supplies to enable the new
settings.
2
The multi-turn limit is valid only when parameter Pn002.2 Absolute Encoder Usage is set to "2". The value will
be processed in the range of "+32767 to -32768" for other settings even if the value is changed. There is no need to
change the multi-turn limit except for in special cases. Be careful not to change the setting unless necessary.
3
The setting of parameter Pn111 is valid only when parameter Pn110.1 is set to 0.
4
Normally set to "0". When using an external regenerative resistor, set the capacity (W) of the regenerative
resistor.
5
The upper limit is the maximum output capacity (W) of the servo amplifier.
Note* Refer to XtraWare User Manual
Содержание 8U0108-E1-01
Страница 4: ...iv This page intentionally left blank...
Страница 6: ...vi This page intentionally left blank...
Страница 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Страница 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Страница 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Страница 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Страница 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Страница 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Страница 48: ...XtraDrive User Manual Chapter 3 Wiring 3 24 Absolute Serial Encoders Incremental A B C Encoders...
Страница 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Страница 240: ...XtraDrive User Manual Chapter 8 Ratings Specifications and Dimensional Drawings 8 11 8 5 2 XD 04 1 phase 200 V 400 W...
Страница 332: ......