XtraDrive Ratings and Specifications (continued)
XtraDrive Model
XD-
P3
P5
01
02
04
05
08
10
15
20
30
Speed Control Range
1:5000 (The lowest speed of the speed control range is the point just
before the motor stops under full-load condition.)
Load Regulation
0 to 100% load: 0.01% maximum (at rated speed)
Voltage
Regulation
Rated Voltage ±10%: 0% (at rated speed)
Speed
R
egulat
ion
*
Temperature
Regulation
25 ± 25°C: ±0.1% max. (at rated speed)
Frequency Characteristics
400Hz (at J
L
= J
M
)
Torque Control Tolerance
(Repeatability)
±2%
Perform
a
nc
e
Soft Start Time Setting
0 to 10s (Can be set individually for acceleration and deceleration)
Reference
Voltage**
±6V
DC
(Variable setting range: ±2 to ±10V
DC
) at rated torque (positive
torque reference with positive reference), input voltage: ±12V
(maximum).
Input Impedance
About 14k
Ω
Speed R
eferen
ce
Input
Circuit Time
Constant
—
Reference
Voltage**
±3V
DC
(Variable setting range: ±1 to ±10V
DC
) at rated torque (positive
torque reference with positive reference), input voltage: ±12V
(maximum)
Input Impedance
About 14k
Ω
T
o
rque
Re
fe
re
nc
e
Input
Circuit Time
Constant
About 47µs
Rotation Direction
Selection
With P control signal
Speed
and T
orqu
e C
ontr
ol M
odes
Input S
ign
als
C
ontac
t
Speed
Re
fe
re
nc
e
Speed Selection
With forward/reverse current limit signal (speed 1 to 3 selection),
servomotor stops or another control method is used when both are
OFF.
Bias Setting
0 to 450rpm (setting resolution: 1rpm)
Feed Forward Compensation 0 to 100% (setting resolution: 1%)
Pe
rf
or
m
a
n
Positioning Completed Width
Setting
0 to 250 reference units (setting resolution: 1 reference unit)
Type
Sign + pulse train, 90° phase difference 2-phase pulse (A phase + B
phase), or CCW + CW pulse train
Form
Line driver (+5V level), open collector (+5V or +12V level)
Re
fe
re
nc
e
Puls
e
Frequency
500/200kpps maximum (line driver/open collector).
Control Signal
Clear Signal (input pulse form identical to reference pulse)
Posit
ion C
ontro
l M
ode
Input S
ign
als
Built-in Open-Collector Power
Supply***
+12V (1k
Ω
built-in resistor)
*
Speed regulation is defined as follows:
The motor speed may change due to voltage variations or amplifier drift and changes in processing resistance due
to temperature variation. The ratio of speed changes to the rated speed represents speed regulation due to voltage
and temperature variations.
**
Forward is clockwise viewed from the non-load side of the servomotor, (counterclockwise viewed from the
load and shaft end).
***The built-in open collector power supply is not electrically isolated from the control circuit in the servo amplifier.
Содержание 8U0108-E1-01
Страница 4: ...iv This page intentionally left blank...
Страница 6: ...vi This page intentionally left blank...
Страница 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Страница 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Страница 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Страница 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Страница 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Страница 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Страница 48: ...XtraDrive User Manual Chapter 3 Wiring 3 24 Absolute Serial Encoders Incremental A B C Encoders...
Страница 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Страница 240: ...XtraDrive User Manual Chapter 8 Ratings Specifications and Dimensional Drawings 8 11 8 5 2 XD 04 1 phase 200 V 400 W...
Страница 332: ......