XtraDrive User Manual
Chapter
5
: Parameter Settings and Functions
5-74
5.6.2. Calculating the Regenerative Power Capacity
Simple Calculation Method
When driving a servomotor normally along the horizontal axis, check
the external regenerative resistor requirements using the calculation
method shown below.
Servo Amplifiers with a Capacity of 400W or Less
Servo amplifiers with a capacity of 400W or less do not have built-in
regenerative resistors. The energy that can be absorbed by capacitors is
shown in the following table. If the rotational energy in the servo
system exceeds these values, then connect a regenerative resistor
externally.
Voltage
Applicable Servo
Amplifiers
Regenerative Energy
that Can Be Processed
(Joules)
Comments
XD-P3-**, -P5-**
18.5
200V
XD-01-** to -04-**
37.1
Value when the input voltage
is 200V AC
Calculate the rotational energy in the servo system using the following
equation:
E
S
=
( )
12566
N
x
J
2
M
Joules
Where: J = J
M
+ J
L
J
M
: Servomotor rotor inertia (kg·m
2
) (oz·in·s
2
)
J
L
: Motor axis conversion load inertia (kg·m
2
) (oz·in·s
2
)
N
M
: Rotation speed of the servomotor (rpm)
Servo Amplifier Capacity of 0.8 to 3.0kW
Servomotors with a capacity of 500W to 5kW have built-in regenerative
resistors. The allowable frequencies for just the servomotor during
acceleration/deceleration operation, in the run cycle from 0
maximum rotation speed 0, are summarized in the following table.
Convert the data into the values obtained with actual rotation speed
used and load inertia to determine whether an external regenerative
resistor is needed.
Содержание 8U0108-E1-01
Страница 4: ...iv This page intentionally left blank...
Страница 6: ...vi This page intentionally left blank...
Страница 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Страница 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Страница 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Страница 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Страница 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Страница 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Страница 48: ...XtraDrive User Manual Chapter 3 Wiring 3 24 Absolute Serial Encoders Incremental A B C Encoders...
Страница 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Страница 240: ...XtraDrive User Manual Chapter 8 Ratings Specifications and Dimensional Drawings 8 11 8 5 2 XD 04 1 phase 200 V 400 W...
Страница 332: ......