XtraDrive User Manual
Chapter
5
: Parameter Settings and Functions
5-90
Set the direction of electrical phase. This parameter used to find the electrical
phase in the AB encoder (other than Yaskawa); if you don’t know the
direction, just set unknown direction and XtraDrive will find it automatically.
Pn191.0 Setting
Results
0 Unknown
direction
1 UVW
2 UWV
As mentioned before, the new parameter settings become active only after
the driver has been restarted.