XtraDrive User Manual
Chapter
6
: Servo Adjustment
6-6
6.2.5.
Using the Soft Start Function
The soft start function adjusts progressive speed reference input inside
the servo amplifier so that acceleration and deceleration can be as
constant as possible. To use this function, set the following parameters.
Parameter
Signal
Setting
(ms)
Description
Pn305
Soft Start Acceleration Time
Setting Range: 0 to 10000
Default Setting: 0
Speed Control
Pn306
Soft Start Deceleration Time
Setting Range: 0 to 10000
Default Setting: 0
Speed Control
In the servo amplifier, a speed reference is smoothed by the acceleration
or deceleration value set in Pn305 or Pn306 to provide speed control.
The soft start function enables smooth speed control when non-
progressive speed references are input or when contact input speed
control is used.
Set both Pn305 and Pn306 to “0” for normal speed control, i.e when the
speed reference does not need to be smoothed.
Set these parameters as follows:
•
Pn305: The time interval from the time the motor starts until the
maximum speed is reached.
•
Pn306: The time interval from the time the motor is operating at the
maximum speed until it stops.
Speed reference
Soft start
Maximum speed
Pn305: Set this time interval.
Pn306: Set this time interval.
XtraDrive's internal
speed reference
Maximum speed
Содержание 8U0108-E1-01
Страница 4: ...iv This page intentionally left blank...
Страница 6: ...vi This page intentionally left blank...
Страница 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Страница 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Страница 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Страница 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Страница 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Страница 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Страница 48: ...XtraDrive User Manual Chapter 3 Wiring 3 24 Absolute Serial Encoders Incremental A B C Encoders...
Страница 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Страница 240: ...XtraDrive User Manual Chapter 8 Ratings Specifications and Dimensional Drawings 8 11 8 5 2 XD 04 1 phase 200 V 400 W...
Страница 332: ......