’s outputs and the connected cables carry life-hazardous voltage or current.
►
Always obey the five safety rules and follow the detailed safety instructions below.
Note:
The safety instructions relevant to the
CPC 100
and its accessories (refer to page
Preface-1) also apply to the
CP SB1
. This section lists safety instructions that exclusively apply
to the
CP SB1
.
General
►
Make sure to position the
CP SB1
in a safe area.
►
Before connecting or disconnecting test objects and/or cables, turn off the
CPC 100
by
either the POWER ON/OFF switch or the Emergency Stop button. Never connect or
disconnect a test object while the outputs are active.
►
Even if you switched off the
CPC 100
, wait until the red I/O warning light is fully extinguished.
As long as this warning light is lit, there is still voltage and/or current potential on one or more
of the outputs.
►
When measuring the ratio of power transformers make sure that the test voltage is
connected to the corresponding high-voltage winding, and the voltage of the low-voltage
winding is the one that is measured. Accidentally mixing up the windings can generate life-
threatening voltages within the transformer.
For example: feeding a voltage of 300 V to the low-voltage winding of a power transformer
that has a ratio of 400000 V : 30000 V, induces a voltage of 4000 V in the transformer's
primary winding.
►
Do not operate the
CP SB1
under ambient conditions that exceed the temperature and
humidity limits listed in "Technical Data".
►
If the
CP SB1
or any add-on device or accessory does not seem to function properly, do not
use it anymore. If in doubt, call the OMICRON electronics hotline.
►
Before handling the
CP SB1
or
CPC 100
in any way, connect them with a solid connection
of at least 6 mm² cross-section to equipotential ground. Ground the
CP SB1
as close as
possible to the
CPC 100
.
►
For the connection between the
CPC 100
and
CP SB1
only use the specially manufactured
cables supplied by OMICRON electronics.
DC Output to Test Objects with a High Inductance
When using the DC Output to test power transformers with a high inductance, observe the
following safety instructions:
►
Use the
TRTapCheck
(tap changer winding resistance and on-load tap changer interruption
check) test card only.
►
As long as the
CPC 100
software shows the on-screen message "Switch off in progress",
NEVER connect or disconnect test objects and/or cables.
►
The message "Switch off in progress" notifies you that, while the
CPC 100
is deactivating,
the connected external inductance (this means the test object) still "feeds" voltage potential
back into the
6A DC
output.
►
The existence of this voltage potential at the
6A DC
output is also indicated by a lit LED -
even if the
CPC 100
is switched off.
►
If a test object with a high inductance was connected to the
CPC 100
, short-out the test
object additionally before disconnecting any cables.
The
CP SB1
is a transformer switch box designated for automatically measuring the ratio and
winding resistance, and testing the tap changer of three-phase power transformers. It is an
accessory to the
CPC 100
. Automatic control of the On-Load Tap Changer (OLTC) is included.
Testing of power transformers over all taps and all phases is fully automated. Therefore, no
rewiring is required. The
CP SB1
is controlled from the
CPC 100
via its serial interface. The
results are recorded in the
CPC 100
with the ratio and tap changer test cards, and can be
analyzed with the computer tool set (
CPC 100
Excel File Loader
).
Safety Instructions
Product Description - Designated Use
CP SB1
Содержание CPC 100
Страница 13: ...CPC 100 V 3 20 Introduction 8 Introduction...
Страница 25: ...CPC 100 V 3 20 Current Transformer 10 Current Transformer...
Страница 29: ...CPC 100 V 3 20 Voltage Transformer 4 Voltage Transformer...
Страница 65: ...CP TD1 CP TD1 10 CP TD1...
Страница 75: ...CP SB1 CP SB1 4 CP SB1...