DMTA-10022-01EN, Rev. C, January 2015
Chapter 10
170
Figure 10-3 Mode 1 detection example
Mode 2
Measures the time of flight between the interface (or delay line) echo and first
back-wall echo using a delay line or an immersion transducer (see Figure 10-4 on
page 170).
Figure 10-4 Mode 2 detection example
Mode 3
Uses a delay line or an immersion transducer to measure the time of flight
between one back-wall echo and the next back-wall echo (see Figure 10-5 on
page 171).
Main bang
First back-wall echo
Detection marker
Mode indicator
Main bang
First back-wall echo
Interface echo
Detection bar
Mode indicator
Содержание 45MG
Страница 8: ...DMTA 10022 01EN Rev C January 2015 Table of Contents viii List of Tables 227 Index 229...
Страница 26: ...DMTA 10022 01EN Rev C January 2015 Introduction 16...
Страница 36: ...DMTA 10022 01EN Rev C January 2015 Chapter 1 26...
Страница 42: ...DMTA 10022 01EN Rev C January 2015 Chapter 2 32...
Страница 136: ...DMTA 10022 01EN Rev C January 2015 Chapter 6 126...
Страница 150: ...DMTA 10022 01EN Rev C January 2015 Chapter 7 140...
Страница 157: ...DMTA 10022 01EN Rev C January 2015 Configuring the Instrument 147 Figure 8 3 The COMM screen...
Страница 158: ...DMTA 10022 01EN Rev C January 2015 Chapter 8 148...
Страница 196: ...DMTA 10022 01EN Rev C January 2015 Chapter 10 186...
Страница 208: ...DMTA 10022 01EN Rev C January 2015 Chapter 11 198...
Страница 226: ...DMTA 10022 01EN Rev C January 2015 Appendix A 216...
Страница 232: ...DMTA 10022 01EN Rev C January 2015 Appendix C 222...