Use Pulse Output Function (Constant Pulse
Output)
Overview
Sending pulse output in direction control mode. Turn ON Enable input
at R4.0 and Start input. Pulse output starts at R2.8 and R2.9 (PLS0).
Output pulses are feedback to high-speed counter inside the unit. If a
pre-set value is reached, pulse stops.
Pulse output diagram
10000 pulses at 1 kHz are sent out by Start input.
Enable input (PLS0)
Start input (PLS0)
Pulse train output
0V (24V DC)
Install Pulse I/O unit in slot No. 0
R0
R1
R2
R3
Occupied I/O areas
Direction signal
(PLS0 direction)
32 points input unit
R4
R5
Enable signal
(PLS0 Enable)
Start signal
(PLS0 start)
Pulse output (PLS0 A)
Direction control signal output
Pulse output (PLS0 B)
Counting output
pulse trains with
internal connection
Comparison coincidence signal (CMP0)
current
value
set
value
Frequency (speed) setting changes to 0 when
counter current value coincides with set value.
Stop pulse output at
the moment when
set value is reached.
1000
0
10000 pulse
PLS0 Start input
(R4.1)
Pulse
frequency
Certain number of pulses is sent out when Start
signal is ON.
• When the number of output pulses is extremely small,
pulse may not stop at the pre-set value due to internal
processing (scan time) delay.
• When pulse output is internally connected to counter, the
input mode of counter is automatically configured to the
pulse output. Be careful because previously configured
counter input mode is ignored.
• Within the internal connection, counter and pulse output
are fixed at the corresponding CH.