[16]
OVERRUN
Overrun Flag
0 = Data in RSLT (ADDRx[15:0], x=0~11) is recent conversion result.
1 = Data in RSLT (ADDRx[15:0], x=0~11) is overwritten.
If converted data in RSLT has not been read before new conversion result is loaded to this
register, OVERRUN is set to 1 and previous conversion result is gone. It is cleared by
hardware after ADDR register is read.
This is a read only bit.
[15:0]
RSLT
A/D Conversion Result
This field contains conversion result of ADC.
When DMOF bit (ADCR[31]) set to 0, 12-bit ADC conversion result with unsigned format
will be filled in RSLT (ADDRx[11:0], x=0~11) and zero will be filled in RSLT
(ADDRx[15:12], x=0~11).
When DMOF bit (ADCR[31]) set to 1, 12-
bit ADC conversion result with 2’complement
format will be filled in RSLT(ADDRx[11:0], x=0~11) and signed bits to will be filled in RSLT
(ADDRx[15:12], x=0~11).
Note: Vref voltage comes from
AVDD for 64/48/36-pin package
Single-end Input voltage
Vin (V)
0000_0000_0000
ADC result in RSLT
(ADDRx[11:0], x=0~7)
0000_0000_0001
0000_0000_0010
1111_1111_1111
1111_1111_1110
1111_1111_1101
1 LSB
Vref - 1 LSB
1 LSB = Vref/4096
Figure 6.17-9 ADC Single-end Input Conversion Voltage and Conversion Result Mapping