NuMicro® NUC029LEE/NUC029SEE
32-bit Arm
®
Cortex
®
-M0 Microcontroller
Aug, 2018
Page
270
of
497
Rev 1.00
N
U
MICRO
®
N
UC02
9L
E
E
/N
UC029
S
E
E
T
E
CHN
ICA
L R
E
F
E
R
E
NC
E
M
A
NU
A
L
1 = Auto-reload mode.
Note:
If there is a transition at this bit, it will cause CNR2 and CMR2 be cleared.
[18]
CH2INV
PWM-Timer 2 Output Inverter Enable (PWM Timer 2 For Group A)
0 = Inverter Disabled.
1 = Inverter Enabled.
[17]
CH2PINV
PWM-Timer 2 Output Polar Inverse Enable (PWM Timer 2 For Group A)
0 = PWM2 output polar inverse Disabled.
1 = PWM2 output polar inverse Enabled.
[16]
CH2EN
PWM-Timer 2 Enable (PWM Timer 2 For Group A)
0 = Corresponding PWM-Timer Stopped.
1 = Corresponding PWM-Timer Start Running.
[15:12]
Reserved
Reserved.
[11]
CH1MOD
PWM-Timer 1 Auto-Reload/One-Shot Mode (PWM Timer 1 For Group A And PWM
Timer 5 For Group B)
0 = One-shot mode.
1 = Auto-reload mode.
Note:
If there is a transition at this bit, it will cause CNR1 and CMR1 be cleared.
[10]
CH1INV
PWM-Timer 1 Output Inverter Enable (PWM Timer 1 For Group A And PWM Timer 5
For Group B)
0 = Inverter Disable.
1 = Inverter Enable.
[9]
CH1PINV
PWM-Timer 1 Output Polar Inverse Enable (PWM Timer 1 For Group A And PWM
Timer 5 For Group B)
0 = PWM1 output polar inverse Disabled.
1 = PWM1 output polar inverse Enabled.
[8]
CH1EN
PWM-Timer 1 Enable (PWM Timer 1 For Group A And PWM Timer 5 For Group B)
0 = Corresponding PWM-Timer Stopped.
1 = Corresponding PWM-Timer Start Running.
[7:6]
Reserved
Reserved.
[5]
DZEN23
Dead-Zone 2 Generator Enable (PWM2 And PWM3 Pair For PWM Group A)
0 = Disabled.
1 = Enabled.
Note:
When Dead-zone generator is enabled, the pair of PWM2 and PWM3 becomes a
complementary pair for PWM group A.
[4]
DZEN01
Dead-Zone 0 Generator Enable (PWM0 And PWM1 Pair For PWM Group A, PWM4
And PWM5 Pair For PWM Group B)
0 = Disabled.
1 = Enabled.
Note:
When Dead-zone generator is enabled, the pair of PWM0 and PWM1 becomes a
complementary pair for PWM group A and the pair of PWM4 and PWM5 becomes a
complementary pair for PWM group B.
[3]
CH0MOD
PWM-Timer 0 Auto-Reload/One-Shot Mode (PWM Timer 0 For Group A And PWM
Timer 4 For Group B)
0 = One-shot mode.
1 = Auto-reload mode.
Note:
If there is a transition at this bit, it will cause CNR0 and CMR0 be cleared.