![Nuvoton NuMicro NUC029 Series Скачать руководство пользователя страница 247](http://html1.mh-extra.com/html/nuvoton/numicro-nuc029-series/numicro-nuc029-series_technical-reference-manual_1720306247.webp)
NuMicro® NUC029LEE/NUC029SEE
32-bit Arm
®
Cortex
®
-M0 Microcontroller
Aug, 2018
Page
247
of
497
Rev 1.00
N
U
MICRO
®
N
UC02
9L
E
E
/N
UC029
S
E
E
T
E
CHN
ICA
L R
E
F
E
R
E
NC
E
M
A
NU
A
L
Timer External Control Register (TEXCON)
Register
Offset
R/W
Description
Reset Value
TEXCON0
T0x14 R/W
Timer0 External Control Register
0x0000_0000
TEXCON1
T0x34 R/W
Timer1 External Control Register
0x0000_0000
TEXCON2
T0x14 R/W
Timer2 External Control Register
0x0000_0000
TEXCON3
T0x34 R/W
Timer3 External Control Register
0x0000_0000
31
30
29
28
27
26
25
24
Reserved
23
22
21
20
19
18
17
16
Reserved
15
14
13
12
11
10
9
8
Reserved
7
6
5
4
3
2
1
0
TCDB
TEXDB
TEXIEN
RSTCAPSEL
TEXEN
TEX_EDGE
TX_PHASE
Bits
Description
[31:8]
Reserved
Reserved.
[7]
TCDB
Timer External Counter Input Pin De-Bounce Enable Bit
0 = TMx pin de-bounce Disabled.
1 = TMx pin de-bounce Enabled.
If this bit is enabled, the edge detection of TMx pin is detected with de-bounce circuit.
[6]
TEXDB
Timer External Capture Input Pin De-Bounce Enable Bit
0 = TMx_EXT pin de-bounce Disabled.
1 = TMx_EXT pin de-bounce Enabled.
If this bit is enabled, the edge detection of TMx_EXT pin is detected with de-bounce
circuit.
[5]
TEXIEN
Timer External Capture Interrupt Enable Bit
0 = TMx_EXT pin detection Interrupt Disabled.
1 = TMx_EXT pin detection Interrupt Enabled.
If TEXIEN enabled, Timer will raise an external capture interrupt signal and inform to CPU
while TEXIF flag is set to 1.
[4]
RSTCAPSEL
Timer External Reset Counter / Timer External Capture Mode Selection
0 = Transition on TMx_EXT pin is using to save the TDR value into TCAP.(event capture
function)
1 = Transition on TMx_EXT pin is using to reset the 24-bit up counter.(event reset counter
function)
[3]
TEXEN
Timer External Pin Function Enable Bit
This bit enables the RSTCAPSEL function on the TMx_EXT pin.