MS51
Nov. 28, 2019
Page
153
of 491
Rev 1.00
MS51
32K
SE
RIES
TE
CHNICAL RE
F
EREN
CE MA
N
UAL
ADCCON0
– ADC Control 0 (Bit-addressable)
Register
SFR Address
Reset Value
ADCCON0
E8H, all page
0000_0000b
7
6
5
4
3
2
1
0
ADCF
ADCS
ETGSEL1
ETGSEL0
ADCHS3
ADCHS2
ADCHS1
ADCHS0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Bit
Name
Description
7
ADCF
ADC flag
This flag is set when an A/D conversion is completed. The ADC result can be read. While this
flag is 1, ADC cannot start a new converting. This bit is cleared by software.
6
ADCS
A/D converting software start trigger
Setting this bit 1 triggers an A/D conversion. This bit remains logic 1 during A/D converting
time and is automatically cleared via hardware right after conversion complete. The meaning
of writing and reading ADCS bit is different.
Writing:
0 = No effect.
1 = Start an A/D converting.
Reading:
0 = ADC is in idle state.
1 = ADC is busy in converting.
5:4
ETGSEL[1:0]
External trigger source select
When ADCEX (ADCCON1.1) is set, these bits select which pin output triggers ADC
conversion.
00 = PWM0.
01 = PWM2.
10 = PWM4
11 = STADC pin.