MS51
Nov. 28, 2019
Page
380
of 491
Rev 1.00
MS51
32K
SE
RIES
TE
CHNICAL RE
F
EREN
CE MA
N
UAL
EIE1
– Extensive Interrupt Enable 1
Register
SFR Address
Reset Value
EIE1
9CH, Page 0
0000 _0000 b
7
6
5
4
3
2
1
0
-
-
EPWM3
EPWM2
EPWM1
EWKT
ET3
ES_1
-
-
R/W
R/W
R/W
R/W
R/W
R/W
Bit
Name
Description
0
ES1
Enable serial port 1 interrupt
0 = Serial port 1 interrupt Disabled.
1 = Serial port 1Interrupt Enable. When interrupt generated TI_1 (S1CON.1) or RI_1 (S1CON.0)
set 1.