In transmit direction, the ISO 7816 sends data to ISO 7816-3 host controller, first. After the period is
greater than (16.5 or 22.5, by T bit setting), the ISO 7816-3 host controller begin to send the data.
Block Guard Time
Last Receiver Data
Transmitter Data
Figure 6.10-5 Transmit Direction Block Guard Time Operation
In receive direction, the ISO 7816-3 host controller sends data to ISO 7816-3, first. If the ISO 7816-3
sends data to ISO 7816-3 host controller at the time which is less than (16.5 or 22.5, by T bit
setting),the block guard time interrupt BGTIF (ScnIS[3]) is generated when RXBGTEN (SCnCR1[5])
and BGTIEN (ScnIE[3]) are enabled.
Block Guard Time
Last Transmitter Data
Receiver Data
Figure 6.10-6 Receive Direction Block Guard Time Operation
Extra Guard Time is EGT (SCnEGT[7:0]),it only affects the data transmitted by ISO 7816-3 interface,
the format is shown as Figure 6.10-7.
Start
Start
D1
D2
D3
D4
D5
D6
D7
D8
P
EGT
Stop bit
Figure 6.10-7 Extra Guard Time Operation