3.5 Programming the Setup Functions
3.5.5 Calibration ([MENU] Button
_
Setup
_
Calibration)
The EasyTrak™ PTZ dome camera is equipped with Auto-calibration which is capable
of maintaining accurate operation through constant self-correction. Once this function is
enabled, EasyTrak™ PTZ dome will go through a series of Pan/Tilt movement and align
its vertical and horizontal position against several check points. Any changes in it posi-
tion through external forces will be automatically corrected from this point on.
1. Press the [Menu] button on the Controller Keyboard. Select the ‘SETUP’ option. Scroll
down to ‘CALIBRATION,’ then press the Joystick handle to the right to access the sub-
menu.
2. Scroll down to ‘AUTO CALIBRATION’ and press the Joystick handle to the right to
enable the function ‘ON.’
3. Finish the programming by scrolling down to the bottom to ‘SAVE AND EXIT.’
Note:
You must ‘SAVE AND EXIT’ to finalize the programming, pressing [ESC] button
while programming will exit programming without saving.
CALIBRATION
ORIGIN RESET
ORIGIN POSITION
ORIGIN OFFSET MOVE
AUTO CALIBRATION : OFF
SAVE AND EXIT