17
2.1.8 EasyTrak™ PTZ Dome Camera Address (ID)
Each EasyTrak™ PTZ dome camera must have a unique address (ID). Identical IDs on the
same line may damage the control circuit caused by an electrical short. When installing
multiple cameras or a DVR, it is recommended that cameras ID’s be indentical
to the camera port of the DVR.
Cam Port 1 = Dome ID 1, Cam Port 2 = Dome ID 2 ... Cam Port 16 = Dome ID 16.
If more than 16 PTZ cameras are installed using two or more DVRs the following formula
is usedful to determine the Dome ID: ID = 16x (n-1) +m (Where n = number of DVR, m =
Camera Port)
Refer to Figure.9 for setting the EasyTrak™ PTZ dome camera address (ID) and
protocol selection.
Figure.9 Setting the EasyTrak™ PTZ camera address (ID) and protocol
2. Installation and Configuration
.
.
9
9
S3
S2
0
.
S1
9
.~
999
001
DOME ID
S1
S2
S3
1
2
3
4
5
6
7
8
9
0
3
2
6
5
4
8
7
9
1
0
1
2
3
4
5
6
7
8
9
0
1
0
D1 D4
S4
. .
on
D5 D8
S5
. .
on
D9 D12
S6
..
on