3.2.0 Alarm ([MENU] Button
_
Alarm)
The Alarm function is designed to trigger specific pre-programmed functions of the Easy-
Trak™ PTZ dome camera when there is changes in the input status. The PTZ dome camera
reports the alarm state to the Controller Keyboard.
Press the [Menu] button on the Controller Keyboard, the OSD (On Screen Display) Main
menu appears on the screen. Select the ‘ALARM’ option, then press the Joystick handle to
the right to access its sub-menu.
Triggered Alarm (shown above) Executes as Follows:
Alarm 01 recalls Pattern 01, after
completion of Pattern 01, Alarm 02~03 will run Preset 48 followed by Preset 01.
Note:
There are total of 9 levels (Including 0) of priority. Levels 1~8 supports Presets(Pxx)
only. However, the hightest priority level ‘0,’ supports sophisticated functions such as
Pattern(Pxx), Scan(Axx), and Tour(Txx).
3.2 Programming the Alarm
NO:
Alarm Input Number
FUNC:
Priority 1~8 (Preset), Priority 0 (Pattern, Scan, Tour)
PRI:
Lower Number = Higher Priority
IN:
NO/NC - Normally Open/Closed, OFF - Ignore
OUT:
R01 - Relay Out 1, R02 - Relay Out 2, OFF - No Input
HLD:
01~99 sec. (Alarm held for set amount of time)
LATCH:
ON (Shows ALL Alarms including past Alarm),
OFF (Shows ACTIVATED Alarms ONLY)
ALARM SETUP
NO FUNC PRI IN OUT HLD LATCH
01 P01 0 OFF OFF 001 OFF
02 048 3 OFF OFF 001 OFF
03 001 1 OFF OFF 001 OFF
04 --- 3 OFF OFF 001 OFF
SAVE AND EXIT
05 --- 3 OFF OFF 001 OFF
06 --- 3 OFF OFF 001 OFF
07 --- 3 OFF OFF 001 OFF
08 --- 3 OFF OFF 001 OFF
MAIN MENU
FUNCTION
ALARM
SCREEN
CAMERA
SETUP
EXIT MENU