HOSE INSTALLATION
HOSE INSTALLATION TIPS
5. All hoses change in length slightly when pressure is applied. Hoses must have
enough slack to relieve stressing the connections.
6. Make sure the hose being installed is routed with the proper bend radius to prevent
kinking, flow restrictions or hose failures at the hose connection.
HOSE
MINIMUM
SIZE
BEND RADIUS
in
(mm)
1/2"
7
(177.8)
3/4"
9.5
(241.3)
1"
12
(304.8)
1-1/4"
16.5
(419.1)
7. Hoses should be used within the following ranges of temperature.
TEMPERATURE RANGE
°F
(
°
C)
HYDRAULIC FLUID
14 to 176
(-10 to +80)
ATMOSPHERIC
14 to 122
(-10 to +50)