138
-
TROUBLESHOOTING
CHECKING BOOSTED PRESSURE
EXTREMELY HIGH PRESSURE OIL!
NPK gauge assembly,
P/N L017-8000
is available to directly check the boosted
pressure on all Material Processors. The pressure intensifier’s have three test ports as
shown.
L017-8000 GAUGE ASSEMBLY
g23
L017-4020
guage: 0 - 15,000 psi
(
0 - 1000 bar
)
f1
L007-6630 female swivel adapter
f2
K023-6690 male adapter
PROCEDURE:
1. Remove a plug from one of the test ports and install the male adapter (f2). Choose
the port that will give you the best gauge clearance and viewing.
2. Install the gauge (g23) into the swivel adapter (f1). (Use thread sealant).
3. Install the gauge and swivel adapter onto the male adapter.
(No thread sealant
required.)
4. Close the jaws all the way. Pressure will rise to the point where intensification starts
(P1 on page 133). Then it will go up to the full boosted pressure of approximately
12,000 psi
(800 bar)
. When the clicking of the booster slows, it is at full
intensification, click…click…click…etc., is normal. If the clicking continues rapidly
and will not slow down, there may be a problem with the intensifier or Material
Processor cylinder assemblies.
5. Open the jaws all the way. You will now read the relief setting of the jaw open
circuit. Note that the intensifier only works on jaw close. Jaw open sees the
Material Processor’s or the carrier’s relief valve pressure setting, whichever is
lower.
NOTE:
IF ADDITIONAL ASSISTANCE IS REQUIRED, CALL THE NPK SERVICE
DEPARTMENT AT 1-800-225-4379.
Содержание M20C
Страница 23: ... 23 SERIAL NUMBER LOCATION M20 ...
Страница 24: ... 24 SERIAL NUMBER LOCATION M28 ...
Страница 25: ... 25 SERIAL NUMBER LOCATION M38 ...
Страница 149: ... 149 WARRANTY STATEMENTS ...
Страница 150: ... 150 WARRANTY STATEMENTS ...
Страница 152: ... Copyright 2018 NPK Construction Equipment Inc www npkce com M000 9600I 10 18 Material Processor Instruction Manual ...