CHECKING THE HYDRAULIC FLOW AT RATED PRESSURE
5
out port
6
in port
fm1
load valve
fm2
flow/temperature
display
fm3
flow/temperature switch
fm4
pressure gauge
(Typical loading type flow meter)
1. Installation of the loading type flow meter.
Install the flow meter (t36) between the Material Processor close (m3) and open
lines (m4) as shown. Typically, the jaw close line is on the left and the jaw open is
on the right of the Material Processor
(looking from the operator’s seat)
.
2. Determine the return line pressure
(pressure drop)
.
Open both shut-off valves (k4) and energize the Material Processor close switch.
Measure the pressure on the flow meter gauge (fm2) with the load valve (fm1) in the
full open position.