146
-
TROUBLESHOOTING
ROTATION
IF THE UNIT WILL NOT ROTATE
1. Check the rotation circuit hydraulic flow per the chart above.
a. If the flow is within specification, install gauges into the rotation hydraulic
circuit hose lines.
b. Position the attachment so it will not rotate.
c. Attempt to rotate the unit in both directions. Each gauge should read 2000 psi
(138 bar)
.
d. If 2000 psi (138 bar) is not achieved, adjust the cross port relief valve
cartridges (ma4) on the counterbalance valve (BO).
e. If adjustment is not possible, call the NPK Service Department at 1-800-225-
4379.
2. Check motor shaft and pinion gear.
UNIT WILL NOT HOLD POSITION
Follow steps 1a through 1e above.