TROUBLESHOOTING
TROUBLESHOOTING GUIDE FOR LOW POWER
RELIEF VALVE CHECKS
PROBLEM
CAUSE
CHECK
REMEDY
Operating pressure
is at 3,625 psi (
250
bar
),
but the
intensifier does not
click.
Booster sequence
valve cartridge.
Observe sequence
valve operation.
(See
"PRESSURE
INTENSIFIER
SEQUENCE AND
RELIEF VALVE
ACTUATION"
)
Replace the
sequence valve
cartridge. (
NOTE:
The sequence valve
cartridge is not
adjustable
.)
Check the o-rings
and backup rings of
the sequence valve
cartridge.
Replace the o-rings
and backup rings of
the sequence valve
cartridge.
Booster control
valve assembly.
Dis-assemble the
main valve and
inspect the spring,
plungers and for
free movement of
the spool.
Polish or replace as
necessary.
Booster assembly
Dis-assemble the
main valve and
inspect the piston
assembly, seals,
poppets and seats.
Polish or replace as
necessary.