Installation and Deinstallation
Internal OD-sensors
The internal OD-sensors are integrated in the material
unwinder. Precondition for activating the sensors is,
that they are connected to the ALS 30x.
Two unwinders can be connected overall. Each
unwinder requires a cable kit.
Prerequisite:
– Cable kit (article number A9767)
Connecting
Plug both cables with the female connectors to the
unwinder [88A].
Plug both cables with the male connectors to the
machine: Connections [89A+B] or [89C+D].
Activating
Warning
, if the critical roll diameter is reached:
Set the required minimum diameter in
MACHINE SETUP > Material warning
.
Error message
, if the material roll is completely
unreeled:
Set
MACHINE SETUP > Material end err
to „On“.
[87] Cable kit for internal OD-control (article number A9767).
[88] Connections at the unwinder.
[89] Connections for OD-sensors.