Installation Manual
ALS 30x
02/2016 | 00
42
Installation and Deinstallation
Adjusting the Wenglor photoelectric sensor
automatically
Only for Wenglor sensors (old standard, replaced since
9/2011 by Novexx sensor).
Call up
MACHINE SETUP > Auto Sensor Adj.
– The label material is fed slowly until the next gap
between labels (punch) is reached. The photoelec-
tric label sensor is automatically adjusted in the
process.
Adjusting the Wenglor photoelectric sensor
manually
Only for Wenglor sensors (old standard, replaced since
9/2011 by Novexx sensor).
For dispensing label material with a low contrast, it can
be necessary to adjust the label sensor manually:
Call up
MACHINE SETUP > Sensor Adjust
.
– Display:
Place backing paper in the fork of the photoelectric
sensor.
Press the
key, until the LED [69A] on the photo-
electric sensor lights up.
Press the
key and keep it pressed just beyond
the point where the LED goes out.
Note the displayed value (value 1).
Place label material in the fork of the photoelectric
sensor.
– The LED will light back up.
Press the
key and keep it pressed just beyond
the point where the LED goes out.
Note the displayed value (value 2).
Calculate value 3:
– Value 3= ( value 1 + (value 2 - value 1) / 2)
Set value 3 by means of the two arrow keys and ac-
knowledge the adjustment by pressing the
key.
Sensor Adjust
Manual:
xx%
[69] LED (A) at the (Wenglor) photoelectric label sensor
A
Содержание ALS 30 Series
Страница 1: ...Edition 2 1 2016 Translation of original version INSTALLATION MANUAL ALS 30x Labeler...
Страница 2: ......
Страница 4: ...Installation Manual ALS 30x 02 2016 4 Contents...
Страница 15: ...Installation Manual ALS 30x 02 2016 00 15 Technical Data 3 Dimensions ALS 30x Part 2...
Страница 58: ......
Страница 59: ...Novexx Solutions GmbH Ohmstra e 3 85386 Eching Germany 49 8165 925 0 www novexx com...