Installation Manual
ALS 30x
02/2016 | 00
44
Installation and Deinstallation
Connection Diagram
[71] Connection diagram alternativ label sensor. Jumper descripti-
Example: capacitive label sensor
– Application: transparent Labels
– Order numbers: A7775 (di-soric sensor including
mounting material and connection cable);
A101452 (sensor only)
– See
www.di-soric.de
Installation:
Tools:
– Hexagon socket drivers 4/6 mm
Turn out screw [72C] and remove the dispensing
edge [72E].
Remove the screws from the bottom ends of the
holding rods. Take off the dispensing edge
holder [72D].
Push the sensor holder [72A] onto the holding rods
and fix it with the thumb screw [72B].
Reinstall dispensing edge holder and dispensing
edge.
Connect the cable.
+24V
+24V
NPN-Configuration
NPN-Signal
PNP-Signal
PNP-Configuration
2,2k
1k
1k
1,5k
Signal
Input
GND
Jumper
(default: open)
1
4
3
2
2,2k
CPU
Sensor
connector
[72] L-shape dispensing edge with capacitive label sensor