Installation Manual
ALS 30x
02/2016 | 00
41
Installation and Deinstallation
Switching the Novexx sensor - PNP/NPN
Default setting: NPN
Switching between NPN/PNP:
Press the button [68A] for at least 6 s, until the status
LEDs [68B] flash 2x.
Finding out the current setting:
Move some label material through the sensor fork
and watch the LEDs.
Compare the result with the table:
Mode
Label
LED
Output
Wenglor (NPN)
Yes
On
Low
No
Off
High
Novexx (PNP)
Yes
On
High
No
Off
Low
Novexx (NPN)
Yes
Off
Low
No
On
High
[Tab. 2] Overview: LED activity and output levels with or without
Label.
[68] Switching the Novexx sensor between PNP and NPN.
PNP/NPN min. 6 s