Novatest S.r.l.
Manual for Multichannel Ultrasonic Pile Integrity Tester
73
parameters which have been set, press Cancel for not. Other
parameters need to be set for only once and it is not required to set
every time. Default of each parameter is the value set at last time.
1. Sampling interval
Select Sampling interval from 17 options including 0.025, 0.05,
0.1, 0.2, 0.4, 0.8, 1.6, 3.2, 6.4, 12.8, 25.6, 51.2, 102.4, 204.8, 409.6,
819.2 and 1638.4. The default is 0.8
μ
s, which is applicable to most
test conditions.
2. Number of waveform points
Number of sample points of collected single-channel waveform
every time: there are 4 options (512, 1024, 2048 and 4096). The
default is 1024. (Suggestion: Do not input large value without special
requirement, otherwise it will negatively affect the speed in dynamic
collection)
3. Transmit voltage
Select excitation voltage value when ultrasonic stimulated
emission transducer generates ultrasonic pulse, there are several
options including 65, 250, 500 and 1000. The default is 500V,
which is applicable to most test conditions. If other test conditions
remain unchanged, the higher transmit voltage is, the stronger
received signal is.
4. Test direction
It may select test upward or downward. The default is upward.