Novatest S.r.l.
Manual for Multichannel Ultrasonic Pile Integrity Tester
70
wave, which means search between maximum and minimum acoustic
speed. If selected, search will be limited within acoustic speed range,
if not, the range will not be limited.
4. Stops sampling after transducer coming to pile head
After have selected this option, it will prompt to finish test and
save data when pile length is in zero point in sampling. If not, test
will continue even pile length is over zero point.
5. Acoustic time corrected value of pipe and coupling water
layer
Figure 4.5 Acoustic time corrected value of pipe and coupling water layer
Press Calculate button to enter into interface as shown (in