Novatest S.r.l.
Manual for Multichannel Ultrasonic Pile Integrity Tester
184
Figure F1.17 Schematic Graph of Test Line and Test Point
F1.4.2 Ultrasonic test
1. Test requirements
1
)
Remain the test system and test parameters unchanged in
test;
2
)
Transducer shall keep close contact with concrete test
surface through couplant, no silt or air is allowed in
coupling layer.
3
)
Transmission pathway of ultrasonic parallel to
reinforcement bar axis nearby shall be avoided in test, if not,
the shortest distance between connection line of two
transducers and this reinforcement bar shall not be less than
1/6 distance in ultrasonic test.