Manual for Multichannel Ultrasonic Pile Integrity Tester
117
5. Test Distance
Test distance refers to the distance of dissemination of acoustic
wave, i.e. the centre-to-centre spacing between transmitting and
receiving transducers, in other words, the distance between two test
surfaces of the object which generally refers to the value of thickness,
which range is 1
∼
5000mm.
6.2.2
Advanced parameter
Press Advanced button in parameter interface to switch to
corresponding property page (as shown in Figure 6.3), Sampling
interval, Transmit voltage, Zero acoustic time and other parameters
may be set up at this page.
After all parameters being set up, press OK button, then all
setting ups are valid and those setting up values of every parameter
will be written into initialization files and return to basic parameter
setup interface; press Cancel button then all setting ups are invalid
and return to basic parameter setup interface.
Press Reset button in Advanced parameter setup interface to pop
up dialogue box inquiring “Whether restore parameter to factory
setting?”; press Yes button to restore all parameters to factory setting
and No for not.
Other parameters need to be set for only once and it is not
required to set every time.