Novatest S.r.l.
Manual for Multichannel Ultrasonic Pile Integrity Tester
60
Chapter 4 Cross-hole sonic logging
software for testing pile integrity
Press Detecting Integrity of Pile button in startup interface to
enter into main interface of pile test software as shown in Figure 4.1,
it is applicable to integrity test of concrete cast-in-place pile with
built-in pipe.
3.1 Main interface
The main interface of the pile test software is composed of three
parts as follow:
function button area, single-channel waveform
area and data graphic area
. There are two kinds of optional
display modes for main interface to select in View: 1*6 or 2*3. 1*6
means that single-channel waveform with 6 profiles displays in the
same row (as shown in Figure 4.1a), 2*3 means that single-channel
waveform with 6 profiles displays in two rows (as shown in Figure
4.1b).