Novatest S.r.l.
Manual for Multichannel Ultrasonic Pile Integrity Tester
158
Creation function after the data analysis of all the piles completed,
and then modify based on the draft, the test report should include the
following contents:
1
)
The information of the project and the test
;
2
)
The
Plane Graph
of the engineering pile positions
;
3
)
The summary of testing results of ultrasonic test method
;
4
)
The test report of single pile by cross-hole Sonic Logging
method
;
5
)
The acoustic velocity depth and amplitude depth curve for
each profile of each testing pile as well as its critical values,
mean of acoustic velocity and amplitude, and the acoustic
shadow graph of Oblique test method
6
)
Analysis specification for defect position and degree of the
pile body.
NOTE: After analysis of all the data and no question
confirmed, the data in the device can be removed for saving the
disc space.