6 - TROUBLESHOOTING
6-3
Underfloor flighting is
noisy.
Flighting connection to powerhead shaft is
loose.
Remove flange connector bolts and pull out the
flighting and ensure all hardware is tightened.
Center gearbox spline connection is not
straight.
Ensure gearbox is set straight into the U-trough.
Flighting is bent.
Remove U-Trough flighting. Check for
straightness by rolling across flat concrete area.
Straighten or replace as necessary.
Power Sweep engaged
and running, but not
advancing
Backboard catching on bin floor.
Ensure backboard clearance is at 1/4” from grain
bin floor.
Rubber on wheel wore down.
Replace with new rubber drive wheel.
Grain condition wet, hard-packed, moldy
Sweep will perform poorly if grain is out of
condition
End wheel contacting bin wall or protruding
grain bin bolts.
Adjust sweep away from bin wall, and or cut or
grind protruding bolts.
U-Trough auger is unable
to move the grain that the
sweep is dumping into
the center hopper.
Obstruction in center hopper.
Remove obstruction.
Intermediate hopper(s) are open, flooding the
U-Trough auger.
Close intermediate hoppers.
Flighting is not timed correctly on the U-Trough
auger.
Pull out underfloor flighting, ensure that flighting is
not damaged. (Flighting must make a continuous
spiral).
Troubleshooting Field Problems (Cont.)
Содержание The Grain Handler 10
Страница 12: ...1 6 1 GENERAL INFORMATION This Page Is Intentionally Left Blank...
Страница 40: ...2 SAFETY INFORMATION 2 28 This Page Is Intentionally Left Blank...
Страница 90: ...4 WORKING OPERATIONS 4 12 This Page Is Intentionally Left Blank...
Страница 108: ...5 MAINTENANCE 5 18 This Page Is Intentionally Left Blank...
Страница 112: ...6 TROUBLESHOOTING 6 4 This Page Is Intentionally Left Blank...
Страница 120: ...8 FORMS AND DECLARATIONS 8 2 This Page Is Intentionally Left Blank...
Страница 128: ...i 6 www norwoodsales com 1 800 446 0316...
Страница 129: ......