January 2007
Upgrading to High Capacity
1002rp Server Maintenance and Diagnostics
183
For instructions about attaching the cable, refer to
Meridian 1 and
CallPilot Server Configuration
(555-7101-222
)
or
Succession CSE
1000 and CallPilot Server Configuration
(555-7101-510).
Note:
Ensure that a single-point ground reference is available for all
the power outlets serving the CallPilot server and its peripherals.
Before the CallPilot server installation, a qualified electrician must
implement the single-point ground reference requirement between
the power outlets of the CallPilot server and the power outlets of the
switch.
14
Power up the server and log on to Windows.
Result:
The Windows New Hardware Found Wizard screen
appears.
15
Wait 10 minutes for the server to return to full service.
16
Click Next.
17
Select the presented Nortel MPB driver and click Next.
18
Repeat the previous two steps each time the Windows New
Hardware Found Wizard screen appears.
19
Restart the server.
Note:
After restarting the server, you receive a dialog box indicating
you have new hardware. Click OK.
20
Run the Configuration Wizard to configure the new hardware.
For instructions, refer to the
Installation and Configuration Task List
(555-7101-210
)
.
ATTENTION
Before clicking Next to install the hardware driver,
wait 10 minutes or until you see the dialog box
“CallPilot is running and is able to accept calls”
;
otherwise the server could display a blue screen and
then restart. If this happens, the server may not
recognize the installed boards.
Содержание 1002rp
Страница 6: ...Standard 1 11 6 CallPilot...
Страница 14: ...Contents Standard 1 11 14 CallPilot...
Страница 30: ...Troubleshooting your CallPilot system Standard 1 11 30 CallPilot...
Страница 92: ...Using CallPilot Manager to monitor hardware Standard 1 11 92 CallPilot...
Страница 107: ...January 2007 Using CallPilot system utilities 1002rp Server Maintenance and Diagnostics 107 Figure 13 Legend Help tab...
Страница 108: ...Using CallPilot system utilities Standard 1 11 108 CallPilot...
Страница 138: ...Replacing basic chassis components Standard 1 11 138 CallPilot...
Страница 150: ...Replacing media drives Standard 1 11 150 CallPilot Figure 31 Replace media drive step 1 G101739...
Страница 156: ...Replacing media drives Standard 1 11 156 CallPilot...
Страница 190: ...Replacing voice processing boards Standard 1 11 190 CallPilot...
Страница 216: ...Index Standard 1 11 216 CallPilot...
Страница 217: ......