January 2007
Upgrading to High Capacity
1002rp Server Maintenance and Diagnostics
179
4
Remove the server cover.
For instructions on removing the server cover, see “Removing the
front bezel and server cover” on page 110.
5
Disconnect the CT Bus cable (if present).
6
Ensure that the current configuration is as follows (this is standard
for a 96-channel configuration):
a.
There is an existing MPB96 board in PCI slot 3.
b.
There is an existing Intel D/480JCT-2T1 PCI card in slot 4, and
its SW100 ID rotary dial switch is set to 0.
c.
There is an existing Intel D/480JCT-2T1 PCI card in slot 5, and
its SW100 ID rotary dial switch is set to 1.
7
Remove any termination jumpers from the Intel D/480JCT-2T1 PCI
cards. For jumper location, see Figure 35 on page 177.
8
Plug the first additional MPB96 card into PCI slot 6.
9
On the first additional Intel D/480JCT-2T1 PCI card:
a.
Set the card’s SW100 ID rotary dial switch to 2.
b.
Ensure that there are no termination jumpers installed on P700.
c.
Plug the card into PCI slot 7.
10
On the second additional Intel D/480JCT-2T1 PCI card:
a.
Set the card’s SW100 ID rotary dial switch to 3.
b.
Ensure that there are no termination jumpers on P700 pins 3
and 4.
c.
Plug the card into PCI slot 8.
11
Plug the second additional MPB96 card into PCI slot 9.
12
Connect the 7 drop CT Bus cable to ensure that the connectors are
connected to the end cards and no connector is left dangling at any
end of the cable.
13
Replace the server cover.
14
Replace the front bezel and lock it.
15
Reconnect the peripheral device and power cables.
Содержание 1002rp
Страница 6: ...Standard 1 11 6 CallPilot...
Страница 14: ...Contents Standard 1 11 14 CallPilot...
Страница 30: ...Troubleshooting your CallPilot system Standard 1 11 30 CallPilot...
Страница 92: ...Using CallPilot Manager to monitor hardware Standard 1 11 92 CallPilot...
Страница 107: ...January 2007 Using CallPilot system utilities 1002rp Server Maintenance and Diagnostics 107 Figure 13 Legend Help tab...
Страница 108: ...Using CallPilot system utilities Standard 1 11 108 CallPilot...
Страница 138: ...Replacing basic chassis components Standard 1 11 138 CallPilot...
Страница 150: ...Replacing media drives Standard 1 11 150 CallPilot Figure 31 Replace media drive step 1 G101739...
Страница 156: ...Replacing media drives Standard 1 11 156 CallPilot...
Страница 190: ...Replacing voice processing boards Standard 1 11 190 CallPilot...
Страница 216: ...Index Standard 1 11 216 CallPilot...
Страница 217: ......