![Nortel 1002rp Скачать руководство пользователя страница 168](http://html1.mh-extra.com/html/nortel/1002rp/1002rp_maintenance-and-diagnostics_1707105168.webp)
RAID operations
Standard 1.11
168
CallPilot
Full data backup
Verifying consistency on the drives
This optional consistency check on the RAID system’s logical drive
ensures that the data on the drives is identical. If any errors are found,
they are corrected automatically. Perform a consistency check
before
you split the RAID system pack. A good data backup on an offline drive
will be important if you need to revert to the CallPilot system from an
unsuccessful upgrade or update. The consistency check can take up to 2
hours to complete.
To perform a consistency check
1
Restart the CallPilot system and press Ctrl+M when prompted, to
enter the RAID setup utility during bootup.
2
From the Management Console, select Check Consistency.
Result:
The Logical Drives Configured dialog box displays.
3
Use the arrow key to highlight the first drive to be checked.
4
Press the space key to select the drive.
5
Press F10 to check consistency.
Result:
The “Check Consistency?” confirm dialog box appears.
6
Select YES and press Enter.
ATTENTION
As an extra precaution, it is recommended that a full
system backup be performed PRIOR to performing a
RAID-split. For more information on system backups refer
to the CallPilot Manager online help.
Содержание 1002rp
Страница 6: ...Standard 1 11 6 CallPilot...
Страница 14: ...Contents Standard 1 11 14 CallPilot...
Страница 30: ...Troubleshooting your CallPilot system Standard 1 11 30 CallPilot...
Страница 92: ...Using CallPilot Manager to monitor hardware Standard 1 11 92 CallPilot...
Страница 107: ...January 2007 Using CallPilot system utilities 1002rp Server Maintenance and Diagnostics 107 Figure 13 Legend Help tab...
Страница 108: ...Using CallPilot system utilities Standard 1 11 108 CallPilot...
Страница 138: ...Replacing basic chassis components Standard 1 11 138 CallPilot...
Страница 150: ...Replacing media drives Standard 1 11 150 CallPilot Figure 31 Replace media drive step 1 G101739...
Страница 156: ...Replacing media drives Standard 1 11 156 CallPilot...
Страница 190: ...Replacing voice processing boards Standard 1 11 190 CallPilot...
Страница 216: ...Index Standard 1 11 216 CallPilot...
Страница 217: ......