January 2007
Replacing basic chassis components
1002rp Server Maintenance and Diagnostics
135
JP5—Disarming no power in the bottom bay
If you are operating with one power supply, you can disable sensing of
no power from the bottom power supply. To do this, install a jumper on
jumper block 1, JP5.
Ensure that the functioning power supply is installed in the upper power
bay.
JP4
Not used.
JP3—LED display
Install a jumper on jumper block 1, JP3, to configure the alarm board to
send alarm signals to the full array of LEDs. This is the default setting
and the required setting for normal server operation.
If this jumper is not installed over both pins, the alarm board does not
send the correct format of signals to the front panel display.
Содержание 1002rp
Страница 6: ...Standard 1 11 6 CallPilot...
Страница 14: ...Contents Standard 1 11 14 CallPilot...
Страница 30: ...Troubleshooting your CallPilot system Standard 1 11 30 CallPilot...
Страница 92: ...Using CallPilot Manager to monitor hardware Standard 1 11 92 CallPilot...
Страница 107: ...January 2007 Using CallPilot system utilities 1002rp Server Maintenance and Diagnostics 107 Figure 13 Legend Help tab...
Страница 108: ...Using CallPilot system utilities Standard 1 11 108 CallPilot...
Страница 138: ...Replacing basic chassis components Standard 1 11 138 CallPilot...
Страница 150: ...Replacing media drives Standard 1 11 150 CallPilot Figure 31 Replace media drive step 1 G101739...
Страница 156: ...Replacing media drives Standard 1 11 156 CallPilot...
Страница 190: ...Replacing voice processing boards Standard 1 11 190 CallPilot...
Страница 216: ...Index Standard 1 11 216 CallPilot...
Страница 217: ......